1CT70Heat PumpThermostat Wiring Guide
10Typical wiring hookup of CT70 with jumper intact.M8504W2W1XOEGY1RLBL1 (HOT)L21POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQ
11AMANA! Jumper these two terminals if both are present# This terminal must be connected to transformer common.$ Remove this factory-installed jumper
12BARD/JANITROL/TAPPAN/WILLIAMSON! This terminal must be connected to transformer common.# Leave factory-installed jumper in place.$ Connect multiple
13ARCOAIRE/SNYDER GENERAL/COMFORTMAKER! This terminal must be connected to transformer common.# Leave factory-installed jumper in place.Wiringterminal
14B.D.P. (BRYANT-DAY/NIGHT-PAYNE)! This terminal must be connected to transformer common.# Leave factory-installed jumper in place.$ Connect multiple
15CARRIER! This terminal must be connected to transformer common.# Leave factory-installed jumper in place.WiringterminalfunctionExistingthermostatwir
16FRIEDRICH! This terminal must be connected to transformer common.# Leave factory-installed jumper in place.$ Tape off the end of the wire. Jumper is
17HEIL QUAKER/WHIRLPOOL/TEMPSTAR! This terminal must be connected to transformer common.# Leave factory-installed jumper in place.Wiringterminalfuncti
18LENNOX! This terminal must be connected to transformer common.# Leave factory-installed jumper in place.RWiringterminalfunctionExistingthermostatwir
19RHEEM/RUUD! This terminal must be connected to transformer common.# Leave factory-installed jumper in place.WiringterminalfunctionExistingthermostat
20TRANE/AMERICAN STANDARD! This terminal must be connected to transformer common.# Leave factory-installed jumper in place.$ Tape off end. CT70 replac
21YORK/BORG WARNER/LUXAIRE (MONCRIEF, FRASER-JOHNSTON)! This terminal must be connected to transformer common.# Connect multiple second stage heating
22YORK/BORG WARNER! This terminal must be connected to transformer common.# Remove factory-installed jumper.WiringterminalfunctionExistingthermostatwi
69-0866—2 C.H. Rev. 01-95 www.honeywell.com/yourhomeAutomation and Control SolutionsHoneywell International Inc.1985 Douglas Drive NorthGolden
3HOW TO USE THIS GUIDEBefore you disconnect the wires and remove your existing thermostat, be sure this new thermostat, see the CT70 wiring hookup dia
5TABLE OF CONTENTSHow to Use This Guide ... 3Heat Pumps are Different ...
6HEAT PUMPS ARE DIFFERENTHeat pump systems usually have a supplemental, Second Stage heating system that operates only when necessary. This heat pump
7HEAT PUMPS ARE TWO SYSTEMS IN ONEIn mild weather, virtually all of the demand for heat in buildings can be met by the heat pump compressor. This Firs
8DEFINITIONS OF TERMINAL FUNCTIONSEach terminal of the CT70 controls a different heat pump function. Here is a list of the possible heat pump function
9FAN:When this terminal is activated, the fan is on. With the fan switch in the auto position, the fan cycles on and off with the heat pump. With the