1 63-2051—4J. H. • Rev. 9-92 • ©Honeywell Inc. 1992 • Form Number 63-2051—4
T451, T651, T694 Thermostats provide on-off
control of valves, fans, motors, contactors, electric
heat elements, duct furnaces and fan coil units in
heating/cooling systems. Switching subbases pro-
vide manual control of heating, cooling and fan.
T451A, T651A, T694A,B,D,F
Light Duty
Line Voltage Thermostats
Thermostats use spst or spdt snap switches activated
by bimetal sensor.
T451A/T651A mount on standard vertical or horizon-
tal junction box.
Options include adjustable range stops, locking cover,
concealed setpoint, locking setpoint, positive off con-
trol, cover thermometer.
T451A provides heating control only.
T651A provides heating and cooling control.
T694A,B,D,F supplied with switching subbase to pro-
vide manual control of heating, cooling and fan.
Q473A,B switching subbase available for T451A/
T651A.
Automatic cooling anticipator for 120, 208, 240 and
277 Vac.
T694A
T694B,D,F
T451A,
T651A
CONTENTS
Specifications ................................................. 2
Ordering Information..................................... 2
Installation ..................................................... 4
Checkout......................................................... 7
Zobrazit stránku 0
1 2 3 4 5 6 7 8

Shrnutí obsahu

Strany 1 - Line Voltage Thermostats

1 63-2051—4J. H. • Rev. 9-92 • ©Honeywell Inc. 1992 • Form Number 63-2051—4T451, T651, T694 Thermostats provide on-offcontrol of valves, fans, m

Strany 2 - Ordering Information

2T451A, T651A, T694A,B,D,FSPECIFICATIONS • ORDERING INFORMATIONSpecificationsSUPER TRADELINE MODELTRADELINE models are selected and packaged to provid

Strany 3 - COOL HEAT COM

3 63-2051—4T451A, T651A, T694A,B,D,FSPECIFICATIONSELECTRICAL RATINGS (A):Voltage (Vac)120 208/240/277Full Load 8 4aLocked Rotor 48 24aWider temperat

Strany 4 - Installation

4T451A, T651A, T694A,B,D,FINSTALLATIONFig. 2—T694A,B,D,F mounting dimensions in in. [mm].11332[36]1532[35]478[124]42932[125 ]4050607080903932

Strany 5 - Fig. 3—Mounting T451A/T651A

5 63-2051—4T451A, T651A, T694A,B,D,FINSTALLATION1. Before mounting thermostat, connect system wiringto proper terminals at rear of thermostat. Follow

Strany 6 - INSTALLATION

6T451A, T651A, T694A,B,D,FINSTALLATIONFig. 6—T694A in heating-cooling system withindependent valve and fan circuits.Fig. 7—T694B connected for positiv

Strany 7 - Checkout

7 63-2051—4T451A, T651A, T694A,B,D,FCHECKOUTCheckoutAfter the thermostat is wired and mounted, perform thefollowing system checkout procedure.T451/T65

Strany 8 - QUALITY IS

8Home and Building Control Home and Building Control Helping You Control Your WorldHoneywell Inc. Honeywell Limited—Honeywell Limitée1985 Douglas Driv

Komentáře k této Příručce

Žádné komentáře