Honeywell UDA2182 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Měření, testování a kontrola Honeywell UDA2182. Honeywell UDA2182 User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 258
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - January 2009

Honeywell Process Solutions UDA2182 Universal Dual Analyzer Product Manual 70-82-25-119 January 2009

Strany 2 - Notices and Trademarks

x UDA2182 Universal Dual Analyzer Product Manual January 2009 Tables Table 3-1 Procedure for Unpacking and Preparing the UDA2182 __________________

Strany 3 - About This Document

Configuration 88 UDA2182 Universal Dual Analyzer Product Manual January 2009 Table 6-11 Logic Configuration Sub-menu selection Parameter Selecti

Strany 4 - Symbol Definitions

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 89 6.13 Auxiliary Configuration Overview The Auxiliary group has four

Strany 5 - Contents

Configuration 90 UDA2182 Universal Dual Analyzer Product Manual January 2009 Accessing Auxiliary Menu • Press Setup to display the Main menu. •

Strany 6

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 91 Sub-menu selection Parameter Selection or Range of Setting Paramete

Strany 7

Configuration 92 UDA2182 Universal Dual Analyzer Product Manual January 2009 6.14 PID Control Configuration Overview PID (Option) - Proportional

Strany 8

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 93 While TRV is active, the output can be adjusted using manual mode fro

Strany 9

Configuration 94 UDA2182 Universal Dual Analyzer Product Manual January 2009 Accessing Control Menu (See “Maintenance” Menu item (Section 6.18),

Strany 10

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 95 Sub-menu selection Parameter Selection or Range of Setting Parameter

Strany 11 - Figures

Configuration 96 UDA2182 Universal Dual Analyzer Product Manual January 2009 Sub-menu selection Parameter Selection or Range of Setting Paramete

Strany 12

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 97 Table 6-14 PID Tuning Sub-menu selection Parameter Selection or Rang

Strany 13 - 1 Introduction

3/08 UDA2182 Universal Dual Analyzer Product Manual xi Table 11-1 Cal History items _________________________________________________________ 189 T

Strany 14 - Introduction

Configuration 98 UDA2182 Universal Dual Analyzer Product Manual January 2009 Sub-menu selection Parameter Selection or Range of Setting Paramete

Strany 15 - 1.2 Features

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 99 Sub-menu selection Parameter Selection or Range of Setting Parameter

Strany 16

Configuration 100 UDA2182 Universal Dual Analyzer Product Manual January 2009 6.15 Auto Cycling Configuration 6.15.1 Overview Auto cycling prov

Strany 17 - 2 Specifications

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 101 6.15.3 Auto Cycling Configuration Table 6-16 Auto Cycling Configurat

Strany 18 - Specifications

Configuration 102 UDA2182 Universal Dual Analyzer Product Manual January 2009 Sub-menu selection Parameter Selection or Range of Setting Paramet

Strany 19 - 2.2 CE Conformity (Europe)

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 103 Sub-menu selection Parameter Selection or Range of Setting Paramete

Strany 20

Configuration 104 UDA2182 Universal Dual Analyzer Product Manual January 2009 Sub-menu selection Parameter Selection or Range of Setting Paramet

Strany 21 - 3.1 Overview

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 105 6.16 Variables Configuration Overview The Variables menu allows yo

Strany 22 - 3.3 Mounting

Configuration 106 UDA2182 Universal Dual Analyzer Product Manual January 2009 6.17 Communication Configuration Overview The communication menu al

Strany 23 - Panel Mounting Procedure

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 107 Sub-menu selection Parameter Selection or Range of Setting Paramete

Strany 24 - Unpacking

xii UDA2182 Universal Dual Analyzer Product Manual January 2009 Figure 8-2 Resetting ORP Offset ___________________________________________________

Strany 25 - Unpacking

Configuration 108 UDA2182 Universal Dual Analyzer Product Manual January 2009 6.18 Maintenance Configuration Accessing Maintenance Menu • Pres

Strany 26 - Wall Mounting Dimensions

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 109 Sub-menu selection Parameter Selection or Range of Setting Paramete

Strany 27 - 4 Power Wiring

Configuration 110 UDA2182 Universal Dual Analyzer Product Manual January 2009 Sub-menu selection Parameter Selection or Range of Setting Paramet

Strany 28 - Power Wiring

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 111 Sub-menu selection Parameter Selection or Range of Setting Paramete

Strany 29 - 4.4 Installing Power Wiring

Configuration 112 UDA2182 Universal Dual Analyzer Product Manual January 2009 Select Tag and Press “Enter”. Follow the “General Rules for Editin

Strany 30

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 113 Output Level 1 Output Level 2 Output Level 3 Off (default) 0% 25% 50

Strany 31 - Figure 4-1 Power Wiring

Inputs and Outputs Wiring 114 UDA2182 Universal Dual Analyzer Product Manual January 2009 7 Inputs and Outputs Wiring 7.1 Overview Introduction

Strany 32 - 5 Operating the Analyzer

Inputs and Outputs Wiring January 2009 UDA2182 Universal Dual Analyzer Product Manual 115 7.2 General Wiring Practices WARNING Qualified per

Strany 33 - 5.2 Analyzer Overview

Inputs and Outputs Wiring 116 UDA2182 Universal Dual Analyzer Product Manual January 2009 Conform to code Instrument wiring should conform to re

Strany 34 - 5.3 Key Navigation

Inputs and Outputs Wiring January 2009 UDA2182 Universal Dual Analyzer Product Manual 117 7.3 Inputs and Outputs Introduction The analyzer ca

Strany 35 - 5.4 Displays Overview

Introduction January 2009 UDA2182 Universal Dual Analyzer Product Manual 1 1 Introduction 1.1 Overview Multi-function instrument The UDA2182 Unive

Strany 36 - Online Functions

Inputs and Outputs Wiring 118 UDA2182 Universal Dual Analyzer Product Manual January 2009 Wiring terminals and board location L2NL1Input 1 Boar

Strany 37 - 5.5 Input Displays

Inputs and Outputs Wiring January 2009 UDA2182 Universal Dual Analyzer Product Manual 119 Table 7-2 Procedure for installing Input and Output wi

Strany 38 - 5.6 PID Displays

Inputs and Outputs Wiring 120 UDA2182 Universal Dual Analyzer Product Manual January 2009 7.4 Direct pH/ORP Input Wiring Diagrams Durafet III 1

Strany 39 - PID LOOP 1

Inputs and Outputs Wiring January 2009 UDA2182 Universal Dual Analyzer Product Manual 121 Durafet II 151413121110987654321SignalNameWireColorR

Strany 40 - AUTO CYCLE 1

Inputs and Outputs Wiring 122 UDA2182 Universal Dual Analyzer Product Manual January 2009 Glass Meredian II 151413121110987654321SignalNameWire

Strany 41 - Operating the Analyzer

Inputs and Outputs Wiring January 2009 UDA2182 Universal Dual Analyzer Product Manual 123 ORP 151413121110987654321SignalNameWireColorReference

Strany 42 - Operating the Analyzer

Inputs and Outputs Wiring 124 UDA2182 Universal Dual Analyzer Product Manual January 2009 HPW7000 151413121110987654321SignalNameWireColorRefer

Strany 43

Inputs and Outputs Wiring January 2009 UDA2182 Universal Dual Analyzer Product Manual 125 HB Series pH or ORP 151413121110987654321SignalNameWir

Strany 44

Inputs and Outputs Wiring 126 UDA2182 Universal Dual Analyzer Product Manual January 2009 7.5 pH Input from External Preamplifier/Cap Adapter W

Strany 45 - 5.8 Pharma Display

Inputs and Outputs Wiring January 2009 UDA2182 Universal Dual Analyzer Product Manual 127 Durafet II External Preamp (-) 10 Volt Supply1514131

Strany 46

Introduction 2 UDA2182 Universal Dual Analyzer Product Manual January 2009 Outputs Two standard Analog outputs 0 –20 or 4–20 mAdc, 750 ohms maxim

Strany 47 - 80.00PCT Warn

Inputs and Outputs Wiring 128 UDA2182 Universal Dual Analyzer Product Manual January 2009 Durafet II Cap Adapter (-) 10 Volt Supply151413121110

Strany 48

Inputs and Outputs Wiring January 2009 UDA2182 Universal Dual Analyzer Product Manual 129 Durafet III Cap Adapter (-) 10 Volt Supply15141312111

Strany 49 - 5.9 Cation Calc Display

Inputs and Outputs Wiring 130 UDA2182 Universal Dual Analyzer Product Manual January 2009 7.6 Conductivity 4 Wire Cond. 18AWG(Has no shield)98

Strany 50

Inputs and Outputs Wiring January 2009 UDA2182 Universal Dual Analyzer Product Manual 131 7.7 Dissolved Oxygen Some cables have connectors on

Strany 51 - CATION CALC

Inputs and Outputs Wiring 132 UDA2182 Universal Dual Analyzer Product Manual January 2009 GuardEarth GroundBlack Pigtail of CoaxOrangeGreenWire

Strany 52

Inputs and Outputs Wiring January 2009 UDA2182 Universal Dual Analyzer Product Manual 133 7.8 Communications Card TX+43214321TX-Wire to Chassis

Strany 53 - 5.10 Status Display

Inputs and Outputs Wiring 134 UDA2182 Universal Dual Analyzer Product Manual January 2009 7.9 Outputs Power Supply/Analog Output/Relay Output C

Strany 54

Inputs and Outputs Wiring January 2009 UDA2182 Universal Dual Analyzer Product Manual 135 7.10 Option Card 151413121110987654321Analog Output

Strany 55

Input Calibration 136 UDA2182 Universal Dual Analyzer Product Manual January 2009 8 Input Calibration 8.1 Overview Introduction The section desc

Strany 56

Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 137 8.2 Calibration Menu Accessing the Main Calibration Menu and sub

Strany 57 - between the

Introduction January 2009 UDA2182 Universal Dual Analyzer Product Manual 3 1.2 Features Standard and solution temperature compensation Measured pH

Strany 58 - 5.11 Event History

Input Calibration 138 UDA2182 Universal Dual Analyzer Product Manual January 2009 8.3 pH/ORP and Conductivity Overview pH/ORP Calibration Calib

Strany 59

Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 139 8.4 Recommendations for Successful Measurement and Calibration

Strany 60

Input Calibration 140 UDA2182 Universal Dual Analyzer Product Manual January 2009 8.5 pH Calibration 8.5.1 Introduction pH instrument calibrat

Strany 61

Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 141 8.5.2 Calibrating pH Electrodes Using Automatic Buffer recogni

Strany 62 - 5.13 Modbus Communications

Input Calibration 142 UDA2182 Universal Dual Analyzer Product Manual January 2009 Calibration functions Calibrating the pH Offset (Standardizati

Strany 63 - 6 Configuration

Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 143 Procedure Make sure you have selected “PV Type –pH Glass, pH Dur

Strany 64 - 6.2 UDA2182 Block Diagram

Input Calibration 144 UDA2182 Universal Dual Analyzer Product Manual January 2009 Step Action Screen 6 Press Enter IN 1 pH/ORP CalSample CalAu

Strany 65 - 6.3 Main Setup Menu

Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 145 Step Action Screen 12 Once the reading is stable Press Enter “

Strany 66

Input Calibration 146 UDA2182 Universal Dual Analyzer Product Manual January 2009 Table 8-3 Procedure for Buffering Method of Calibrating pH Ele

Strany 67

Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 147 Step Action Screen 6 Once the reading is stable Press Enter “C

Strany 68

Introduction 4 UDA2182 Universal Dual Analyzer Product Manual January 2009 Password protection Keyboard security protects configuration and cali

Strany 69

Input Calibration 148 UDA2182 Universal Dual Analyzer Product Manual January 2009 8.5.4 Sample Method of Calibrating pH Electrodes Recommended

Strany 70

Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 149 Step Action Screen 4 Press Enter IN 1 pH/ORP CalSample CalAut

Strany 71

Input Calibration 150 UDA2182 Universal Dual Analyzer Product Manual January 2009 8.5.5 Viewing and resetting pH Offset and (Standardization) p

Strany 72

Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 151 8.6 ORP Calibration 8.6.1 Introduction ORP calibration consists

Strany 73

Input Calibration 152 UDA2182 Universal Dual Analyzer Product Manual January 2009 Table 8-5 Oxidation-Reduction Potential of Reference Solution

Strany 74

Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 153 Step Action Screen 4 Put the unit in “Hold” mode Remove the el

Strany 75 - 6.6 Inputs Configuration

Input Calibration 154 UDA2182 Universal Dual Analyzer Product Manual January 2009 8.6.3 ORP Calibration Using Voltage Input Calibrates Analyzer

Strany 76

Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 155 Step Action Screen 4 Insert a screwdriver into the tab in the

Strany 77

Input Calibration 156 UDA2182 Universal Dual Analyzer Product Manual January 2009 Step Action Screen 12 Once the reading is stable, if it does

Strany 78

Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 157 8.7 Conductivity Calibration 8.7.1 Introduction Each type of cel

Strany 79

Specifications January 2009 UDA2182 Universal Dual Analyzer Product Manual 5 2 Specifications 2.1 Specifications UDA2182 Universal Dual Analyzer D

Strany 80

Input Calibration 158 UDA2182 Universal Dual Analyzer Product Manual January 2009 8.7.4 Determining TDS conversion factor To determine the TDS

Strany 81

Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 159 8.7.5 Performing Calibration Trim Introduction For most applic

Strany 82

Input Calibration 160 UDA2182 Universal Dual Analyzer Product Manual January 2009 Table 8-8 Conductivity of Potassium Chloride Solutions at 25 °

Strany 83 - Wire Size Sq mm

Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 161 Step Action Screen 5 Press Enter 6 Follow the prompts at the

Strany 84

Input Calibration 162 UDA2182 Universal Dual Analyzer Product Manual January 2009 8.7.6 Resetting Calibration Trim If the calibration is suspec

Strany 85

Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 163 8.7.7 Cation pH Calibration The UDA allows for a sample calibra

Strany 86 - 6.7 Outputs Configuration

Input Calibration 164 UDA2182 Universal Dual Analyzer Product Manual January 2009 Step Action Screen 4 Press Enter CATION PHSample CalpH Offs

Strany 87

Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 165 8.7.8 Resetting pH Offset If the calibration is suspect, you ca

Strany 88 - 6.8 Relays Configuration

Input Calibration 166 UDA2182 Universal Dual Analyzer Product Manual January 2009 8.8 Dissolved Oxygen Calibration Overview The analyzer suppor

Strany 89 - to display the

Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 167 Calibrating a Dissolved Oxygen Probe Using Air Calibration Metho

Strany 90 - See Table 6-3

Specifications 6 UDA2182 Universal Dual Analyzer Product Manual January 2009 UDA2182 Universal Dual Analyzer Control Loop/Outputs Control Loops

Strany 91

Input Calibration 168 UDA2182 Universal Dual Analyzer Product Manual January 2009 Step Action Screen 4 Press Enter Follow the prompts at the t

Strany 92

Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 169 Calibrating a Dissolved Oxygen Probe Using Sample Calibration Me

Strany 93 - 6.9 Alarms Configuration

Input Calibration 170 UDA2182 Universal Dual Analyzer Product Manual January 2009 Step Action Screen 4 Press Enter IN1 DO CALSample CalAir Cal

Strany 94

Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 171 Calibrating the Integral Pressure Sensor Introduction The concen

Strany 95 - 6.10 Monitors Configuration

Input Calibration 172 UDA2182 Universal Dual Analyzer Product Manual January 2009 Step Action Screen 4 Press Enter Follow the prompts at the t

Strany 96

Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 173 before the test was initiated. During this voltage sweep, the pr

Strany 97 - 6.11 Math Configuration

Input Calibration 174 UDA2182 Universal Dual Analyzer Product Manual January 2009 exceeding 0.8 volts, a second process (water reduction) begins

Strany 98 - (Linear Only)

Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 175 Step Action Screen Use to select Bias Scan 4 Press Enter to

Strany 99 - 6.12 Logic Configuration

Input Calibration 176 UDA2182 Universal Dual Analyzer Product Manual January 2009 Step Action Screen 6 Press Enter to save Screen returns to “

Strany 100

Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 177 Resetting Pressure Offset or Bias Volts If the calibration is s

Strany 101 - Configuration

Specifications January 2009 UDA2182 Universal Dual Analyzer Product Manual 7 UDA2182 Universal Dual Analyzer Ethernet TCP/IP Communications Interf

Strany 102 - Select B

Outputs Calibration 178 UDA2182 Universal Dual Analyzer Product Manual January 2009 9 Outputs Calibration 9.1 Overview Introduction The section

Strany 103

Outputs Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 179 9.2 Output Calibration Introduction The UDA2182 is available w

Strany 104 - Configuration

Outputs Calibration 180 UDA2182 Universal Dual Analyzer Product Manual January 2009 WARNING While the unit is powered, a potentially lethal s

Strany 105 - ATTENTION

Outputs Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 181 Procedure Table 9-1 Procedure for Calibrating Analyzer Outputs

Strany 106

Outputs Calibration 182 UDA2182 Universal Dual Analyzer Product Manual January 2009 Step Action Screen 8 Press Enter OUTPUT CALOutput 1Output

Strany 107

Outputs Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 183 Step Action Screen 12 Use to select ” 4 mA Offset” and rep

Strany 108

Outputs Calibration 184 UDA2182 Universal Dual Analyzer Product Manual January 2009 Viewing and resetting 20mA and 4mA Offset If the calibratio

Strany 109 - Table 6-14 PID Tuning

Temperature Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 185 10 Temperature Input Calibration 10.1 Overview Int

Strany 110 - Table 6-15 PID Alarms

Temperature Input Calibration 186 UDA2182 Universal Dual Analyzer Product Manual January 2009 10.2 Temperature Input Calibration Introduction T

Strany 111 - – an adjustable overlap of

Temperature Input Calibration January 2009 UDA2182 Universal Dual Analyzer Product Manual 187 Step Action Screen Use the keys to highlight t

Strany 112

ii UDA2182 Universal Dual Analyzer Product Manual January 2009 Notices and Trademarks Copyright 2008 by Honeywell Revision 5 January 2009 WARRA

Strany 113

Specifications 8 UDA2182 Universal Dual Analyzer Product Manual January 2009 ATTENTION The emission limits of EN61326 are designed to provide re

Strany 114

Temperature Input Calibration 188 UDA2182 Universal Dual Analyzer Product Manual January 2009 Viewing and resetting Temperature Offset If the c

Strany 115

Calibration History January 2009 UDA2182 Universal Dual Analyzer Product Manual 189 11 Calibration History 11.1 Overview Calibration History reco

Strany 116 - On-Line mode

Calibration History 190 UDA2182 Universal Dual Analyzer Product Manual January 2009 11.2 Clear Calibration History • Press Setup to display th

Strany 117

Diagnostics and Messages January 2009 UDA2182 Universal Dual Analyzer Product Manual 191 12 Diagnostics and Messages 12.1 Overview Introduction

Strany 118

Diagnostics and Messages 192 UDA2182 Universal Dual Analyzer Product Manual January 2009 12.2 System Status Messages Overview The following ta

Strany 119

Diagnostics and Messages January 2009 UDA2182 Universal Dual Analyzer Product Manual 193 12.3 Calibration Diagnostics pH/ORP/DO All of the pos

Strany 120

Diagnostics and Messages 194 UDA2182 Universal Dual Analyzer Product Manual January 2009 12.4 Auto Cycle Fail Messages Overview Auto Cycle Fail

Strany 121

Diagnostics and Messages January 2009 UDA2182 Universal Dual Analyzer Product Manual 195 12.5 Pharma Fail Messages Overview Pharma Fail is activ

Strany 122

Ethernet and Communications 196 UDA2182 Universal Dual Analyzer Product Manual January 2009 13 Ethernet and Communications 13.1 Overview For all

Strany 123 - Date/Time

Accessories and Replacement Parts List January 2009 UDA2182 Universal Dual Analyzer Product Manual 197 14 Accessories and Replacement Parts List

Strany 124

Unpacking January 2009 UDA2182 Universal Dual Analyzer Product Manual 9 3 Unpacking, Preparation, and Mounting 3.1 Overview Introduction This sec

Strany 125 - *ATTENTION

Accessories and Replacement Parts 198 UDA2182 Universal Dual Analyzer Product Manual January 2009 14.2 Part Numbers Introduction Part numbers

Strany 126 - 7 Inputs and Outputs Wiring

Appendices January 2009 UDA2182 Universal Dual Analyzer Product Manual 199 15 Appendices 15.1 Table of Contents Topic See Page PH/ORP 15.2 App

Strany 127

Appendices 200 UDA2182 Universal Dual Analyzer Product Manual January 2009 15.2 Appendix A – Entering Values for Lead Resistance Compensation (S

Strany 128

Appendices January 2009 UDA2182 Universal Dual Analyzer Product Manual 201 Since the analyzer only allows entry of one wire gauge type, we allow f

Strany 129 - 7.3 Inputs and Outputs

Appendices 202 UDA2182 Universal Dual Analyzer Product Manual January 2009 15.3 Appendix B – Entering Values for Lead Resistance Compensation [Ti

Strany 130 - Inside case with door open

Appendices January 2009 UDA2182 Universal Dual Analyzer Product Manual 203 Because there are two different types of wire used in each lead to the

Strany 131

Appendices 204 UDA2182 Universal Dual Analyzer Product Manual January 2009 15.4 Appendix C - Cyanide Waste Treatment Introduction Uses of cyani

Strany 132

Appendices January 2009 UDA2182 Universal Dual Analyzer Product Manual 205 First Stage of Cyanide Destruction Raise pH and oxidize cyanide Sodium

Strany 133

Appendices 206 UDA2182 Universal Dual Analyzer Product Manual January 2009 Importance of pH control As shown in Figure 15-4, pH has a direct effe

Strany 134

Appendices January 2009 UDA2182 Universal Dual Analyzer Product Manual 207 Batch Treatment Sequence of steps Continuous treatment is shown in Figu

Strany 135

Unpacking 10 UDA2182 Universal Dual Analyzer Product Manual January 2009 3.2 Unpacking and Preparing Procedure Table 3-1 Procedure for Unpacking

Strany 136 - HPW7000

Appendices 208 UDA2182 Universal Dual Analyzer Product Manual January 2009 15.5 Appendix D – Chrome Waste Treatment Use of Chromates Corrosion in

Strany 137 - HB Series pH or ORP

Appendices January 2009 UDA2182 Universal Dual Analyzer Product Manual 209 First Stage of Chrome Removal Lower pH and add reducing agent Sulfuric

Strany 138

Appendices 210 UDA2182 Universal Dual Analyzer Product Manual January 2009 Chrome reduction is slow enough that 10 to 15 minutes may be required

Strany 139

Appendices January 2009 UDA2182 Universal Dual Analyzer Product Manual 211 negative. The chromium, an oxidizing ion, Cr+6, accepts electrons and m

Strany 140

Appendices 212 UDA2182 Universal Dual Analyzer Product Manual January 2009 15.6 Appendix E – Two-cell Applications Ion Exchange Ion exchange ope

Strany 141

Appendices January 2009 UDA2182 Universal Dual Analyzer Product Manual 213 alarms (+ and -) are used. A difference kind of diagnostic can be provi

Strany 142 - 7.6 Conductivity

Appendices 214 UDA2182 Universal Dual Analyzer Product Manual January 2009 Softener Monitor Softener monitoring by conductivity ratio gives a con

Strany 143 - 7.7 Dissolved Oxygen

Appendices January 2009 UDA2182 Universal Dual Analyzer Product Manual 215 SPECIFICCONDUCTIVITYUDA2182ANALYZERCATIONCONDUCTIVITYSAMPLECELL 1 CELL

Strany 144

Appendices 216 UDA2182 Universal Dual Analyzer Product Manual January 2009 15.7 Appendix F – Using a Precision Check Resistor (For Conductivity)

Strany 145 - 7.8 Communications Card

Appendices January 2009 UDA2182 Universal Dual Analyzer Product Manual 217 Example 1: To determine the check resistor value needed to simulate con

Strany 146 - 7.9 Outputs

Unpacking January 2009 UDA2182 Universal Dual Analyzer Product Manual 11 Panel Mounting Dimensions 156[6.14]156[6.14]152[5.98]33.5[1.32]138[5.43]+

Strany 147 - 7.10 Option Card

Appendices 218 UDA2182 Universal Dual Analyzer Product Manual January 2009 15.8 Appendix G – Noise Testing, Dissolved Oxygen Application Hints fo

Strany 148 - 8 Input Calibration

Appendices January 2009 UDA2182 Universal Dual Analyzer Product Manual 219 15.9 Appendix H – DO Probe and Analyzer Tests Before performing air le

Strany 149 - 8.2 Calibration Menu

Appendices 220 UDA2182 Universal Dual Analyzer Product Manual January 2009 Check that analyzer is working 1. Remove power from analyzer. 2. Dis

Strany 150 - Conductivity

Appendices January 2009 UDA2182 Universal Dual Analyzer Product Manual 221 problem is that the cursor is positioned too far to the left or right o

Strany 151

Appendices 222 UDA2182 Universal Dual Analyzer Product Manual January 2009 15.10 Appendix I – Parameters Affecting Dissolved Oxygen Measurement T

Strany 152 - 8.5 pH Calibration

Appendices January 2009 UDA2182 Universal Dual Analyzer Product Manual 223 15.11 Appendix J – Discussion on Chemical Interferences on Measured DO

Strany 153 - Input Calibration

Appendices 224 UDA2182 Universal Dual Analyzer Product Manual January 2009 Faradaic Interferences The DO probe responds to oxygen partial pressu

Strany 154 - Input Calibration

Appendices January 2009 UDA2182 Universal Dual Analyzer Product Manual 225 15.12 Appendix K – Percent Saturation Readout In some special applicati

Strany 155 - Refer to Section 6.4.1 –

Appendices 226 UDA2182 Universal Dual Analyzer Product Manual January 2009 15.13 Appendix L – Leak Detection in PPB Applications Before performin

Strany 156

Appendices January 2009 UDA2182 Universal Dual Analyzer Product Manual 227 15.14 Appendix M – Procedure for Low Level ppb Dissolved Oxygen Testing

Strany 157 - Error Messages:

Unpacking 12 UDA2182 Universal Dual Analyzer Product Manual January 2009 Rear Panel Support Plate Dimensions Figure 3-2 Rear Panel Support Plat

Strany 158 - Calibrate

Appendices 228 UDA2182 Universal Dual Analyzer Product Manual January 2009 9. Return probe to flow chamber and resume nitrogen sparging. 10. Whe

Strany 159 - Adjustment

Appendices January 2009 UDA2182 Universal Dual Analyzer Product Manual 229 15.15 Appendix N – Sample Tap Electrode Mounting Recommendations Overvi

Strany 160

Appendices 230 UDA2182 Universal Dual Analyzer Product Manual January 2009 then the pressure at the sensor is four feet water-column below atmosp

Strany 161 - • DO NOT Remove the

Appendices January 2009 UDA2182 Universal Dual Analyzer Product Manual 231 15.16 Appendix O – Auto Clean and Auto Cal Examples Automatic Cleaning

Strany 162

Appendices 232 UDA2182 Universal Dual Analyzer Product Manual January 2009 Figure 15-9 Auto Clean Setup

Strany 163 - 8.6 ORP Calibration

Appendices January 2009 UDA2182 Universal Dual Analyzer Product Manual 233 Automatic Calibration of ppb Dissolved Oxygen Probe A typical set – up

Strany 164 - – Table

Index 234 UDA2182 Universal Dual Analyzer Product Manual January 2009 15.17 Appendix P – AutoClean and AutoCal Theory and Piping Overview Period

Strany 165

January 2009 UDA2182 Universal Dual Analyzer Product Manual 235 rinse/cleaningsolutionprocesssamplepHelectrodeto processto drain9782S4S1Items out

Strany 166 - Step Action Screen

Index 236 UDA2182 Universal Dual Analyzer Product Manual January 2009 divert the discharge to drain. 3 Relay 2 activates solenoid valve S2 for

Strany 167

January 2009 UDA2182 Universal Dual Analyzer Product Manual 237 Select piping and valves based on chemical resistance and pressure ratings Make t

Strany 168

Unpacking January 2009 UDA2182 Universal Dual Analyzer Product Manual 13 Pipe Mounting The analyzer can be mounted vertically or horizontally on a

Strany 169 - 8.7 Conductivity Calibration

Index 238 UDA2182 Universal Dual Analyzer Product Manual January 2009

Strany 170

January 2009 UDA2182 Universal Dual Analyzer Product Manual 239 Index 3-mode control...91 A

Strany 171

Index 240 UDA2182 Universal Dual Analyzer Product Manual January 2009 Conditional Sequencer Steps...32 Conductivi

Strany 172 - Procedure

January 2009 UDA2182 Universal Dual Analyzer Product Manual 241 L Label...109

Strany 173

Index 242 UDA2182 Universal Dual Analyzer Product Manual January 2009 PID Alarms...97

Strany 174 - In the same screen as “

January 2009 UDA2182 Universal Dual Analyzer Product Manual 243 Slope adjustments...138 Slope Over

Strany 175 - 8.7.7 Cation pH Calibration

Index 244 UDA2182 Universal Dual Analyzer Product Manual January 2009

Strany 176

January 2009 UDA2182 Universal Dual Analyzer Product Manual 245

Strany 177

Honeywell Process Solutions Honeywell 70-82-25-119 Rev.5 2500 W. Union Hill Drive January 2009 Phoenix, Arizona 85027 ©2009 Honeywell International

Strany 178 - Overview

Unpacking 14 UDA2182 Universal Dual Analyzer Product Manual January 2009 Wall Mounting Dimensions The analyzer can be mounted on a wall. Use the

Strany 179

Power Wiring January 2009 UDA2182 Universal Dual Analyzer Product Manual 15 4 Power Wiring 4.1 Overview Introduction This section contains instruc

Strany 180

Power Wiring 16 UDA2182 Universal Dual Analyzer Product Manual January 2009 4.2 General Wiring Practices WARNING Qualified personnel should

Strany 181

Power Wiring January 2009 UDA2182 Universal Dual Analyzer Product Manual 17 4.3 Power Wiring Considerations Recommended wire size Observe all app

Strany 182

January 2009 UDA2182 Universal Dual Analyzer Product Manual iii About This Document Abstract This document provides descriptions and procedures f

Strany 183

Power Wiring 18 UDA2182 Universal Dual Analyzer Product Manual January 2009 Step Action screws that hold the retainer and slide the retainer to

Strany 184 - Test initiation

Power Wiring January 2009 UDA2182 Universal Dual Analyzer Product Manual 19 AC N L2AC Hot L1Case Earth GroundGrounding Studon Case1312111098765

Strany 185 - Display Graph

Operating the Analyzer 20 UDA2182 Universal Dual Analyzer Product Manual January 2009 5 Operating the Analyzer 5.1 Overview Introduction This s

Strany 186

Operating the Analyzer January 2009 UDA2182 Universal Dual Analyzer Product Manual 21 5.2 Analyzer Overview The UDA2182 Universal Dual Analyzer

Strany 187

Operating the Analyzer 22 UDA2182 Universal Dual Analyzer Product Manual January 2009 5.3 Key Navigation Table 5-1 shows each key on the operato

Strany 188 - “IN1 DO CAL”

Operating the Analyzer January 2009 UDA2182 Universal Dual Analyzer Product Manual 23 5.4 Displays Overview Viewing the Displays To view disp

Strany 189 - Reset Bias Volts”

Operating the Analyzer 24 UDA2182 Universal Dual Analyzer Product Manual January 2009 Online Functions Table 5-2 Display Details Functions Deta

Strany 190 - 9 Outputs Calibration

Operating the Analyzer January 2009 UDA2182 Universal Dual Analyzer Product Manual 25 5.5 Input Displays Two Input Display Press Display . Y

Strany 191 - 9.2 Output Calibration

Operating the Analyzer 26 UDA2182 Universal Dual Analyzer Product Manual January 2009 5.6 PID Displays Overview When PID 1 or 2 is active - ther

Strany 192 - WARNING

Operating the Analyzer January 2009 UDA2182 Universal Dual Analyzer Product Manual 27 Changing Parameters on the PID Display When either PID Dis

Strany 193

iv UDA2182 Universal Dual Analyzer Product Manual January 2009 Symbol Definitions The following table lists those symbols used in this document to

Strany 194 - • When all digits have been

Operating the Analyzer 28 UDA2182 Universal Dual Analyzer Product Manual January 2009 5.7 Auto Cycle Displays 5.7.1 Overview Auto Cycling allows

Strany 195 - Outputs Calibration

Operating the Analyzer January 2009 UDA2182 Universal Dual Analyzer Product Manual 29 5.7.3 How it works Each occurrence of a sequence of actio

Strany 196 - Reset 4mA Offset”

Operating the Analyzer 30 UDA2182 Universal Dual Analyzer Product Manual January 2009 5.7.5 Hold Active If Hold Active is enabled in Auto cyclin

Strany 197 - 10.1 Overview

Operating the Analyzer January 2009 UDA2182 Universal Dual Analyzer Product Manual 31 5.7.12 Manual Starting/Stopping the Auto Cycle Pressing En

Strany 198 - ” Input Temp Cal”

Operating the Analyzer 32 UDA2182 Universal Dual Analyzer Product Manual January 2009 5.7.13 Auto Cycle Fail The status message “Auto Cycle n Fa

Strany 199 - (Read only)

Operating the Analyzer January 2009 UDA2182 Universal Dual Analyzer Product Manual 33 5.8 Pharma Display 5.8.1 Overview The Pharma Parameter is

Strany 200

Operating the Analyzer 34 UDA2182 Universal Dual Analyzer Product Manual January 2009 The UDA also supports Pharma Europa (PhEur) section 2.2.38

Strany 201 - Overview

Operating the Analyzer January 2009 UDA2182 Universal Dual Analyzer Product Manual 35 Table 5-6 Selecting the Pharma Test on Display Press Acti

Strany 202 - • Press

Operating the Analyzer 36 UDA2182 Universal Dual Analyzer Product Manual January 2009 5.8.5 Pharma Warning and Fail Signal The Pharma 1 warni

Strany 203 - 12 Diagnostics and Messages

Operating the Analyzer January 2009 UDA2182 Universal Dual Analyzer Product Manual 37 5.9 Cation Calc Display 5.9.1 Overview This group allows

Strany 204 - Table 12-1 Status Messages

3/08 UDA2182 Universal Dual Analyzer Product Manual v Contents 1 INTRODUCTION ...

Strany 205 - Status Message Definition

Operating the Analyzer 38 UDA2182 Universal Dual Analyzer Product Manual January 2009 Degassed CO2 The dual input UDA can also be configured for

Strany 206 - Fail Message Reason

Operating the Analyzer January 2009 UDA2182 Universal Dual Analyzer Product Manual 39 Note: The relationship between the electrolytic conductiv

Strany 207 - Condition

Operating the Analyzer 40 UDA2182 Universal Dual Analyzer Product Manual January 2009 5.9.7 Troubleshooting In normal operation, both the direct

Strany 208 - 13.1 Overview

Operating the Analyzer January 2009 UDA2182 Universal Dual Analyzer Product Manual 41 5.10 Status Display Overview The Status Displays let you s

Strany 209 - 14.1 Overview

Operating the Analyzer 42 UDA2182 Universal Dual Analyzer Product Manual January 2009 Status Display Parameter Status (Read Only) Status Defin

Strany 210 - 14.2 Part Numbers

Operating the Analyzer January 2009 UDA2182 Universal Dual Analyzer Product Manual 43 Status Display Parameter Status (Read Only) Status Defin

Strany 211 - 15 Appendices

Operating the Analyzer 44 UDA2182 Universal Dual Analyzer Product Manual January 2009 Status Display Parameter Status (Read Only) Status Defin

Strany 212

Operating the Analyzer January 2009 UDA2182 Universal Dual Analyzer Product Manual 45 Status Display Parameter Status (Read Only) Status Defin

Strany 213 - Appendices

Operating the Analyzer 46 UDA2182 Universal Dual Analyzer Product Manual January 2009 5.11 Event History Overview Event History records events

Strany 214 - [Titanium Cells]

Operating the Analyzer January 2009 UDA2182 Universal Dual Analyzer Product Manual 47 Clear Event History • Press Setup to display the Main men

Strany 215

vi UDA2182 Universal Dual Analyzer Product Manual January 2009 5.7.12 Manual Starting/Stopping the Auto Cycle ...

Strany 216

Operating the Analyzer 48 UDA2182 Universal Dual Analyzer Product Manual January 2009 5.12 Process Instrument Explorer Software Overview Process

Strany 217 - Titration curve

Operating the Analyzer January 2009 UDA2182 Universal Dual Analyzer Product Manual 49 Infrared communications The infrared connection provides a

Strany 218 - Appendices

Operating the Analyzer 50 UDA2182 Universal Dual Analyzer Product Manual January 2009 5.13 Modbus Communications Overview The UDA2182 provides

Strany 219 - Batch Treatment

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 51 6 Configuration 6.1 Overview Introduction Configuration is a dedicate

Strany 220 - Use of Chromates

Configuration 52 UDA2182 Universal Dual Analyzer Product Manual January 2009 6.2 UDA2182 Block Diagram Overview Signal Connection Key Relay (1-

Strany 221

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 53 6.3 Main Setup Menu Accessing the Main Menu Press Setup. The main

Strany 222

Configuration 54 UDA2182 Universal Dual Analyzer Product Manual January 2009 Proportional Output), Pulse Frequency (Pulse Frequency Type), Freque

Strany 223

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 55 6.4 Basic Configuration Procedure Introduction Each of the Set Up gr

Strany 224 - Reverse Osmosis

Configuration 56 UDA2182 Universal Dual Analyzer Product Manual January 2009 Basic Configuration Procedure Table 6-1 Basic Configuration Procedur

Strany 225 - Parts Rinsing

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 57 6 Enter the Value or Selection Enter Enters value or selection made

Strany 226 - Softener Monitor

3/08 UDA2182 Universal Dual Analyzer Product Manual vii 6.16 Variables Configuration...

Strany 227

Configuration 58 UDA2182 Universal Dual Analyzer Product Manual January 2009 6.5 Analog and Digital Signal Sources Overview This section contain

Strany 228 - (For Conductivity)

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 59 Table 6-3 Analog Signal Sources Analog Signal Description Definitio

Strany 229 - Cell Constant

Configuration 60 UDA2182 Universal Dual Analyzer Product Manual January 2009 PID Out 2 PID Output 2 PID 2 Output in percent (0 to 100). Normal

Strany 230 - Hints for Reducing Noise

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 61 Out 1 Fault Output 1 Fault Out 2 Fault Output 2 Fault Out 3 Fault

Strany 231

Configuration 62 UDA2182 Universal Dual Analyzer Product Manual January 2009 AC 2 Cal 2 Auto Cycle 2 Calibration Point 2 Auto Cycle 2 digital ou

Strany 232

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 63 6.6 Inputs Configuration Overview This group lets you select pH/ORP,

Strany 233

Configuration 64 UDA2182 Universal Dual Analyzer Product Manual January 2009 Sub-menu selection Parameter Selection or Range of Setting Paramete

Strany 234 - Measurement

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 65 Sub-menu selection Parameter Selection or Range of Setting Parameter

Strany 235 - Measured DO Currents

Configuration 66 UDA2182 Universal Dual Analyzer Product Manual January 2009 Sub-menu selection Parameter Selection or Range of Setting Paramete

Strany 236 - Sulfite Based Zero Testing

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 67 Sub-menu selection Parameter Selection or Range of Setting Parameter

Strany 237 - (ppm, mg/L)

viii UDA2182 Universal Dual Analyzer Product Manual January 2009 9 OUTPUTS CALIBRATION...

Strany 238

Configuration 68 UDA2182 Universal Dual Analyzer Product Manual January 2009 Sub-menu selection Parameter Selection or Range of Setting Paramete

Strany 239 - Oxygen Measurement Procedure

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 69 Sub-menu selection Parameter Selection or Range of Setting Parameter

Strany 240 - Example Calculation

Configuration 70 UDA2182 Universal Dual Analyzer Product Manual January 2009 Sub-menu selection Parameter Selection or Range of Setting Paramete

Strany 241 - Recommendations

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 71 Sub-menu selection Parameter Selection or Range of Setting Parameter

Strany 242

Configuration 72 UDA2182 Universal Dual Analyzer Product Manual January 2009 Sub-menu selection Parameter Selection or Range of Setting Paramete

Strany 243 - Low Dissolved Oxygen

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 73 Sub-menu selection Parameter Selection or Range of Setting Parameter

Strany 244 - Figure 15-9 Auto Clean Setup

Configuration 74 UDA2182 Universal Dual Analyzer Product Manual January 2009 6.7 Outputs Configuration Overview This group lets you select the si

Strany 245 - Figure 15-10 Auto Cal Setup

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 75 NOTE 1. The entries for any parameter are in the units of that parame

Strany 246

Configuration 76 UDA2182 Universal Dual Analyzer Product Manual January 2009 6.8 Relays Configuration Overview Programming the relays consists of

Strany 247

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 77 • Press to highlight the desired menu selection then press Enter to

Strany 248 - Index

3/08 UDA2182 Universal Dual Analyzer Product Manual ix 15.13 Appendix L – Leak Detection in PPB Applications...

Strany 249 - Two-Point Calibration

Configuration 78 UDA2182 Universal Dual Analyzer Product Manual January 2009 Sub-menu selection Parameter Selection or Range of Setting Paramete

Strany 250

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 79 Sub-menu selection Parameter Selection or Range of Setting Parameter

Strany 251

Configuration 80 UDA2182 Universal Dual Analyzer Product Manual January 2009 Sub-menu selection Parameter Selection or Range of Setting Paramete

Strany 252

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 81 6.9 Alarms Configuration Overview Alarm 1 through 4 Alarm selections

Strany 253

Configuration 82 UDA2182 Universal Dual Analyzer Product Manual January 2009 Accessing Alarms Menu • Press Setup to display the Main menu. • Us

Strany 254

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 83 6.10 Monitors Configuration Overview Monitor 1, 2, 3, and 4 A Monitor

Strany 255 - W, X, Y, Z

Configuration 84 UDA2182 Universal Dual Analyzer Product Manual January 2009 NOTE 2: For High Monitor If Input greater than setpoint Output = ON

Strany 256

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 85 6.11 Math Configuration Overview The Math group has four Math selecti

Strany 257

Configuration 86 UDA2182 Universal Dual Analyzer Product Manual January 2009 Table 6-10 Math Configuration Sub-menu Parameter Selection or Ran

Strany 258 - SE Asia Countries

Configuration January 2009 UDA2182 Universal Dual Analyzer Product Manual 87 6.12 Logic Configuration Overview The Logic group has four selection

Komentáře k této Příručce