18 69-0395—2
Troubleshooting
Your Honeywell thermostat requires little or no attention. Most problems can generally be
traced to the following:
1 Not applicable on heating-only model.
Problem
Check Action
No heat. system switch. May be in OFF or
COOL position.
Move system switch to HEAT position.
fuse or circuit breaker. If blown or tripped, replace fuse or reset
breaker.
furnace power switch. May be
OFF.
Move switch to ON.
pilot flame (where applicable).
May be out.
Relight pilot flame per furnace
manufacturer instructions.
RH and W thermostat
connections.
Turn Off power to furnace. Check for
correct terminal hookups. Repair any
frayed or broken wires. Firmly tighten all
terminal screws.
1
(continued)